QuantaMaster™ 300
Phosphorescence / Fluorescence Spectrofluorometer

 
  System Enhancements
 
 
QM-300 Phosphorescence Fluorescence Spectrofluorometer Quote
 
Fluorescence Spectroscopy Brochure
 
Fluorescence Spectroscopy One Page Flyer
 
 

QuantaMaster™ 300 System Enhancements

 

Q-50H Steady State Enhancement

Add a high intensity continuous xenon source for excitation. More..

Q-70-30 Tunable Second Emission Detection Channel

Add a continuous excitation source for increased sensitivity in steady state measurement. More..

Q-90A Fluorescence Microscopy Enhancement

Adapt an existing PTI spectrofluorometer to a fluorescence microscope using existing emission monochromator for detection. More...

Q-110A Laser Lifetime Enhancement

Add enhanced fluorescence lifetime measurement capability to a PTI spectrofluorometer. More...

Q-110B Laser Lifetime Enhancement Using Q Switched Laser for Excitation

Add enhanced fluorescence lifetime measurement capability to a PTI spectrofluorometer. More...

Q-250 Lifetime Enhancement

Fluorescence lifetime add on with LED excitation. More...

PM-2 TCSPC LED Lifetime Enhancement

TCSPC Lifetime add-on for QuantaMaster™ systems.More...

 

 

Steady State Enhancement Q-50H

 

The ultimate in Sensitivity!

The Q-50H Steady State Enhancement includes a continuous high intensity xenon source for excitation added to the second entrance port of the excitation monochromator for increased S:N of 20,000:1, detection limit of 400 attomolars of fluorescine. The QuantaMaster™ 300 multi mode detector will allow for this mode of operation. For more information on Steady State systems from PTI check out our QuantaMaster™ 400.

  Q-50H Upgrade to  PTI's QuantaMaster 300 Spectrofluorometer
   

Tunable Second Emission Detection Channel Q-70-30

 

 

The Q-70-30 Second Emission Channel add-on for QuantaMaster™ systems includes a second computer controlled, autocalibrated QuadraScopic™ 300 mm monochromator with triple grating turret for emission wavelength selection (one grating included, others may be selected at time of order), new multi-mode PMT detector, additional optics for the second emission channel of the sample compartment as well as a lid activated shutter.

  Q-70-30 Upgrade to PTI's QuantaMaster 300 Spectrofluorometer
   

Fluorescence Microscopy Enhancement Q-90A

 

Allows emission wavelength selection when coupled to a microscope!

The Q-90A Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source to a microscope and a excitation flipping mirror. For detection, another liquid light guide is mounted to the C-adapter of the microscope and transmits the emission signal to the second entrance port of the emission monochromator of the system. (C mount and adaptor for microscope required but not included)

  Q-90Aa Upgrade to PTI's QuantaMaster 300 Spectrofluorometer
   

Laser Lifetime Enhancement Q-110A

 

235–1000 nm wavelength range!

The Q-110A Laser Lifetime add-on for QuantaMaster™ systems includes a nitrogen pumped dye laser source to provide the excitation illumination, coupling optics, a stroboscopic detector and flipping mirror. For more information on Lifetime systems from PTI check out our LaserStrobe™.

  QuantaMaster 300 Laser Lifetime Upgrade
   

Laser Lifetime Enhancement Q-110B

 

235–1000 nm wavelength range!

The Q-110B Laser Lifetime add-on for QuantaMaster™ systems is designed for use with Q-switched lasers (not included) to provide the excitation illumination, coupling optics, a stroboscopic detector and flipping mirror. For more information on Lifetime systems from PTI check out our LaserStrobe™.

  QuantaMaster 300 Laser Lifetime Upgrade
   

Lifetime Enhancement Q-250

 

Lifetimes down to 100 picoseconds!

The Q-250 Lifetime add-on for QuantaMaster™ systems uses a LED light source for excitation. Included are required optics and adaptors, strobe detector and a flipping mirror for the emission monochromator. LED sources are available but not included. For more information on Lifetime systems from PTI check out our TimeMaster™ 2000.

View LEDs

  Q-250 Upgrade to PTI's QuantaMaster 300 Spectrofluorometer

TCSPC Lifetime Enhancement PM-2

 

Lifetimes < 10 picoseconds!

The PM-2 TCSPC Lifetime add-on for QuantaMaster™ systems offers a wide choice of light sources (not included): LED's, laser diodes or other various lasers sources, such as Q-switched or mode locked lasers for excitation, just choose the one that best suits your specific applications. Included are required optics and adaptors, TCSPC detector, TCSPC electronics and PTI's proprietary acquisition and analytical package. While the light sources are not included, you can buy them all directly from PTI.

  PM 2 Upgrade to PTI's QuantaMaster 300 Spectrofluorometer
   

 

 

 