PTI, Photon Technology International, The Fluorescence Solutions Company

The Fluorescence Solutions Company

 

or

 
   
       
 
 
 

QuantaMaster™ 400
Steady State Spectrofluorometer

 
  System Enhancements
 
 
QM-400 Steady State Spectrofluorometer Quote
 
Fluorescence Spectroscopy Brochure
 
Fluorescence Spectroscopy One Page Flyer
 
 

QuantaMaster™ 400 System Enhancements

 

Q-40G Phosphorescence Enhancement

Add phosphorescence lifetime measurement capability. More...

Q-70N Tunable Second Emission Detection Channel

Add a second emission channel to a system using continuous xenon illumination. More...

Q-7B-40 Second Emission Channel

Add a second emission channel to a system using continuous xenon illumination. More...

Q-80A-40 Fluorescence Microscopy Enhancement

Adapt an existing PTI spectrofluorometer to a fluorescence microscope with a photometer for detection. More...

Q-90A Fluorescence Microscopy Enhancement

Adapt an existing PTI spectrofluorometer to a fluorescence microscope using existing emission monochromator for detection. More...

Q-90B Fluorescence Microscopy Enhancement

Adapt an existing PTI spectrofluorometer to a fluorescence microscope using existing emission monochromator and Liquid Light Guide for detection. More...

Q-110A Laser Lifetime Enhancement

Add enhanced fluorescence lifetime measurement capability to a PTI spectrofluorometer. More...

Q-110B Laser Lifetime Enhancement Using Q Switched Laser for Excitation

Add enhanced fluorescence lifetime measurement capability to a PTI spectrofluorometer.More...

Q-250 Lifetime Enhancement

Fluorescence lifetime add on with LED excitation. More...

Q-730 NIR Enhancement

Time of order substitution enhancement to an NIR system with InGaAs detection of 500 to 1700 nm. More...

Q-731 NIR Enhancement

Time of order substitution enhancement to an NIR system with InGaAs detection of 500 to 1700 nm. More...

Q-73B Extended NIR Enhancement

Time of order substitution enhancement to Q-730 and Q-731 an NIR systems with extended InGaAs detection of 900 to 2200 nm. More...

Q-73E Extended NIR Enhancement

Time of order substitution enhancement to Q-730 and Q-731 NIR systems with extended InGaAs detection of 700 to 1900 nm. More...

Q-73F Extended NIR Enhancement

Time of order substitution enhancement to Q-730 and Q-731 NIR systems with extended InGaAs detection of 1000 to 3200 nm. More...

Q-73G Extended NIR Enhancement

Time of order substitution enhancement to Q-730 and Q-731 NIR systems with extended InGaAs detection of 1500 to 5500 nm. More...

 

 

Phosphorescence Enhancement Q-40G

 

Measure lifetimes greater than 400 nanoseconds!

The Q-40G Phosphorescence Enhancement includes a pulsed xenon light source and excitation and emission flipping mirrors. The QuantaMaster™ 400 multi mode detector will allow for this mode of operation. For more information on Phosphorescence systems from PTI check out our QuantaMaster™ 300.

For older systems please contact your local sales professional.

  Q-40G Upgrade to  PTI's QuantaMaster 400 Spectrofluorometer

Tunable Second Emission Detection Channel Q-70N

 

 

The Q-70N Second Emission Channel add-on for QuantaMaster™ systems includes a second computer controlled, coma aberration corrected, asymmetrical, emission optimized auto calibrated QuadraScopic™ 300 mm monochromator with triple grating turret, new multi-mode PMT detector, additional optics for the second emission channel of the sample compartment as well as a lid activated shutter.

For older systems please contact your local sales professional.

  Q-70N Upgrade to PTI's QuantaMaster 400 Spectrofluorometer
   

Second Emission Channel Enhancement Q-7B-40

 

 

The Q-7B-40 add-on for QuantaMaster™ systems includes a multi mode PMT detector coupled directly to the sample compartment, wavelength selection by means of filters. It can operate in both analog and digital (photon counting) modes. Additional optics for the sample compartment and a lid activated shutter are also included.

For older systems please contact your local sales professional.

  Q-7B-40 Upgrade PTI's QuantaMaster 400 Spectrofluorometer
   

Fluorescence Microscopy Enhancement Q-80A

 

For the most sensitivity
when coupled to a microscope!

The Q-80A Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source of an existing system to a microscope, a excitation flipping mirror and a complete photometer using high sensitivity PMT detection (C port and adaptor for microscope required but not included).

For older systems please contact your local sales professional.

  Q-80A Upgrade PTI's QuantaMaster 400 Spectrofluorometer
   

Fluorescence Microscopy Enhancement Q-80A-40

 

For the most sensitivity
when coupled to a microscope!

The Q-80A-40 Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source of an existing system to a microscope, a excitation flipping mirror and a complete photometer using high sensitivity multi mode PMT detection (C port and adaptor for microscope required but not included).

For older systems please contact your local sales professional.

  Q-80A-40 Upgrade PTI's QuantaMaster 400 Spectrofluorometer
   

Fluorescence Microscopy Enhancement Q-90A

 

Allows emission wavelength selection
when coupled to a microscope!

The Q-90A Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source to a microscope and a excitation flipping mirror. For detection, another liquid light guide is mounted to the C-adapter of the microscope and transmits the emission signal to the second entrance port of the emission monochromator of the system. (C mount and adaptor for microscope required but not included)

For older systems please contact your local sales professional.

  Q-90a Upgrade to PTI's QuantaMaster 40 Spectrofluorometer
   

Fluorescence Microscopy Enhancement Q-90B

 

For selection of emission area on microscope

The Q-90B Fluorescence Microscopy add-on for QuantaMaster™ systems includes a liquid light guide to couple the excitation source to a microscope, for detection, another liquid light guide is mounted to the exit port of a PTI photometer that is mounted on the C-port of the microscope. The emission signal is transmitted back to the second entrance port of the emission monochromator of the system. Flipping mirrors are used to select whether the light is directed from the sample compartment or the microscope. (C mount and adaptor for microscope required but not included)

For older systems please contact your local sales professional.

  Q-90B Upgrade to PTI's QuantaMaster 400 Spectrofluorometer
   

Laser Lifetime Enhancement Q-110A

 

Add fluorescence lifetime capability from
331–1000 nm (235 to 1000 nm optional)

The Q-110A Laser Lifetime add-on for QuantaMaster™ systems includes a nitrogen pumped dye laser source to provide the excitation illumination, coupling optics, a stroboscopic detector and flipping mirror. For more information on Lifetime systems from PTI check out our LaserStrobe™.

For older systems please contact your local sales professional.

  Q-110A Upgrade to PTI's QuantaMaster 400 Spectrofluorometer
   

Laser Lifetime Enhancement Q-110B

 

 

The Q-110B Laser Lifetime add-on for QuantaMaster™ systems is designed for use with Q-switched lasers (not included) to provide the excitation illumination, coupling optics, a stroboscopic detector and flipping mirror. For more information on Lifetime systems from PTI check out our LaserStrobe™.

For older systems please contact your local sales professional.

  Q-110B Upgrade to PTI's QuantaMaster 400 Spectrofluorometer
   

Lifetime Enhancement Q-250

 

Lifetimes down to 100 picoseconds!

The Q-250 Lifetime add-on for QuantaMaster™ systems uses a LED light source for excitation. Included are required optics and adaptors, strobe detector and a flipping mirror for the emission monochromator. LED sources are available but not included. For more information on Lifetime systems from PTI check out our TimeMaster™ 2000.

View LEDs

For older systems please contact your local sales professional.

  Q-250 Upgrade to PTI's QuantaMaster 400 Spectrofluorometer
   

NIR Enhancement Q-730

 

Unmatched NIR capability from 500 to 1700 nm!

The Q-730 NIR add-on for QuantaMaster™ systems uses the existing high intensity 75 watt xenon light source, excitation scanning monochromator and sample compartment but substitutes a high sensitivity TE-cooled InGaAs detector, electronics, lock-in amplifier and chopper for noise suppression, and includes an additional emission 600 groove grating blazed at 1.2 microns. Detection range is from 500 to 1700 nm. For more information on NIR systems from PTI check out our QuantaMaster™ 500.

For older systems please contact your local sales professional.

  Q-730 Upgrade to PTI's QuantaMaster 400 Spectrofluorometer
   

NIR Enhancement Q-731

 

 

The Q-731 NIR add-on for QuantaMaster™ systems uses the existing high intensity 75 watt xenon light source, excitation scanning monochromator and sample compartment but substitutes a high sensitivity TE-cooled InGaAs detector, electronics and includes an additional emission 600 groove grating blazed at 1.2 microns. Because it does not use a chopper and a lock in it is somewhat less sensitive than the Q-731, but at half the cost it is an extremely economical option. Lock-in and chopper can be added at a later date. For more information on NIR systems from PTI check out our QuantaMaster™ 500.

For older systems please contact your local sales professional.

  Q-731 Upgrade to PTI's QuantaMaster 400 Spectrofluorometer
   

NIR Enhancement Q-731 B

 

 

Extended wavelength detector (900 - 2,200 nm) can only be ordered at time of original order to replace standard NIR detector (500 - 1,700 nm) in Q-730

For older systems please contact your local sales professional.

   
   

NIR Enhancement Q-73 E

 

 

Extended wavelength InGaAs detector (700 - 1,900 nm) can only be ordered at time of original order to replace standard NIR detector (500 - 1,700 nm) in Q-730

For older systems please contact your local sales professional.

   
   

NIR Enhancement Q-73 F

 

 

Extended wavelength PbS detector (1000 - 3200 nm) with preamp. Includes grating (300 l/mm blazed at 2000nm) and special NIR lenses. Can only be ordered at time of original order to replace standard NIR detector (500 - 1,700 nm) in Q-730

For older systems please contact your local sales professional.

   
   

NIR Enhancement Q-73 G

 

 

Extended wavelength InSb detector (1500 - 5500 nm) with preamp, liquid N2 cooled. Includes grating (150 l/mm blazed at 4000nm) and special NIR lenses. Can only be ordered at time of original order to replace standard NIR detector (500 - 1,700 nm) in Q-730

For older systems please contact your local sales professional.

   
   

 

 
Home  |  About Us  |  News  |  Events  |  Products  |  Applications  |  Brochures  |  Service  |  Contact Us